DuraSoundClick here for Sales Information and detailsSECTION 10655 - Accordion Folding Partitions shall be DuraSound as manufactured by Won-Door Corporation. Operation:
Shall
be top supported, and manually [electrically] operated. Construction:
Shall consist of two parallel
accordion-type walls of panels independently suspended with no pantographs or interconnections except at the
lead-post. Panels shall be formed of cold rolled vinyl-clad 24-gauge
V-grooved steel. Vinyl shall be permanently bonded by heat pressure
lamination to the steel panel. Panels shall be connected by full height
extruded vinyl hinges. Insulation: Interior surfaces of both walls shall be completely covered with a continuous blanket of 2 lb.density foil-backed fiberglass fastened in place with steel spring-clips. Perimeter Seals: Shall consist of continuous extruded vinyl sweep strips attached to the top and bottom of the partition. Leading edges of lead-posts and receiver posts shall be acoustically sealed by extruded vinyl interlocking seals. Lead-posts:
Shall be of 16-gauge cold rolled steel and shall be connected to the
partition by specially formed steel panels. Lead-post hardware shall
include standard grip-type handles and sliding latch to effect closure.
[Key locks shall be provided if required.] Hanging weight:
shall
be 4.2 pounds per square foot. OPTIONS :
Stabilizer Bar: Shall
consist of a top supported, internally mounted diagonal brace connected to
the lead-post for proper alignment during operation and latching.
[Requires 14" wide header.] Motor operator: Motor-operated folding
partitions shall be driven by means of a roller chain attached to the
stabilizer bar trolley. An internally mounted stabilizer bar shall keep
lead-posts plumb and in proper alignment during operation and insure a
tight fitting closure without the use of mechanical latches. Motor
Operated Assembly: Shall consist of a 115/230 volt single-phase AC Motor
[or 208 volt 3-phase AC gear motor], reversing electro-magnetic starter,
and limit switch. Size of each motor shall be determined by manufacturer
to insure proper operation. ACOUSTICAL PERFORMANCE:
Sound transmission
class (STC) shall be STC 48 when tested in accordance with
requirements of ASTM E-90. COLOURS:
Vinyl finish color
shall be selected by the architect from manufacturer's standard colours. EXECUTION> : PREPARATION BY GENERAL CONTRACTOR
Openings shall be to the dimensions specified, plumb and level. Headers shall be leveled with the finished floor to within +/- 1/4" (.006) tolerance over the entire length of the opening. Contractor is required to supervise
unloading and handling. Store boxes flat (not more than three high) in a
dry area INSPECTION:
Contractor shall
inspect prepared opening and immediately notify the architect, in writing,
of unacceptable conditions. INSTALLATION: Install partitions in accordance with manufacturer's printed instructions. Upon completion of the installation, the General Contractor shall protect partitions from damage and replace or repair subsequent damage so that partitions are acceptable to the architect, at no additional cost to the owner.
REPRESENTATION ACROSS CANADA ~ SALES - INSTALLATION - SERVICE
For labelling information, specifications and architectural details Please call:- 1-888-786-5623 |